Condition for activating the functionalities (P-CHAN-00606)

P-CHAN-00606

Condition for activating the functionalities

Description

This parameter specifies a condition.

If the processing mode complies with the specified condition at program startn, the related functionalities are activated at program start.

 

The corresponding functionalities are defined in P-CHAN-00605 .

The condition is assigned to the corresponding functionality by an index.

Parameter

configuration.path_preparation.fct_condition[<idx>] where idx 0,1

Data type

STRING

Data range

See Condition for activating the functionalities (P-CHAN-00508)

Dimension

----

Default value

ISG_STANDARD

Remarks

Parameter is available as of the following Builds: V2.11.2040.04 ; V2.11.2810.02 ; V3.1.3079.17 ; V3.1.3107.10