These instructions describe the automatic calibration of a tool touch probe with a reference tool.

Calibrating the tool touch probe
Calibrating the tool touch probe

Possible applications

During the calibration, the surface position of the touch probe is determined in Z, the centre point in X and Y and the diameter of the measuring plate.

The velocity-dependent shift of the measurement trigger points are also scanned in the tool touch probe parameters measured. It is therefore practical to repeat a calibration if only the measurement velocity changes.

Prerequisites

To ensure that the calibration of the tool touch probe is executed successfully, the following requirements must be fulfilled:

  1. Tool touch probe is fitted and active
  2. A reference tool of known length and know radius is changed and the tool data is activated.
  3. The required measurement and pre-positioning velocities and the approximate plate diameter were entered in the configuration file.