ID 70617

While measuring on fixed stop the latch condition was valid before reaching the latch start position.

Description

During Measuring to fixed stop, the latch condition set in the axis parameters P-AXIS-00774, P-AXIS-00775 and P-AXIS-00778 was already active although the minimum path set in P-AXIS-00776 and P-AXIS-00777 to activate the latch condition was not completed.

Response

Class

2

Error message output abort program.

Solution

Class

3

Check and modify the axis parameters P-AXIS-00774, P-AXIS-00775 and P-AXIS-00778.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [0.1 10^-3 mm or ø]

Amount of position lag

%3:

Current value [0.1 10^-3 mm or ø]

Position lag limit (P-AXIS-00774)

%4:

Upper limit value [0.1 10^-3 mm or ø]

Limit for movement during fixed stop detection (P-AXIS-00778)

%5:

Current value [0.1 10^-3 mm or ø]

Current value of movement during fixed stop detection.

Error type

1, Error message from NC program.