ID 70621

The measured position is before the release position for probing in the movement block.

Description

When measuring to a fixed stop, a measured value was acquired before the configured enable position for acquiring the measured value (P-AXIS-00776, P-AXIS-00777).

Response

Class

7

Controlled halt of the axis, the control loop is closed.

Solution

Class

6

Check parameterisation for measuring travel to fixed stop (P-AXIS-00774, P-AXIS-00775, P-AXIS-00776, P-AXIS-00777, P-AXIS-00778).

Parameter

%1:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of concerned axis

%2:

Current value [0.1 10^-3 mm or ø]

Measured value acquired

%3:

Current value [0.1 10^-3 mm or ø]

Start position for acquisition of the measured value (a value of zero in connection with value 5 = FALSE, means that the start position is not yet reached). The value is determined by P-AXIS-00776 and/or P-AXIS-00777.

%4:

Current value [-]

Direction of axis motion, TRUE means that the axis was moving in a position direction.

%5:

Current value [-]

Flag indicating whether the start position for acquiring the measured value was overshot. If the flag is TRUE, the start position is in value 3, otherwise it is zero.

Error type

1, Error message from NC program.