ID 22134

Number of measured values of distance control is out of data format.

Description

When the sensor values for distance control were filtered, the number of measured values used for filtering can be specified by the keyword “DISTC_N_CYCLES”.

The number exceeds the permissible range.

Further information on programming distance control in [FCT-M3// Programming]

Response

Class

2

Abort NC program processing. .

Solution

Class

3

Check and modify the value for “DISTC_N_CYCLES” in the NC program.

Parameter

%1:

Error value [-]

Incorrectly programmed value for “DISTC_N_CYCLES”

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

Error type

1, Error message from NC program.