Initial position for simulation drives at controller start (P-AXIS-00792)

P-AXIS-00792

Initial position for simulation drives at controller start

Description

This position defines the initial position which simulation drives assume at controller start. This position is only adopted if the parameter P-AXIS-00791 is activated.

Parameter

antr.simu.initial_position

Data type

SGN32

Data range

MIN_SGN32 ≤ P-AXIS-00792 ≤ MAX_SGN32

Axis types

T, R, S

Dimension

T: 0.1 µm

R,S: 0.0001 °

Default value

0

drive types.

Simulation

Remarks

This parameter is available as of CNC Build V2.11.2055.00