ID 315004

The order of the low-pass filter for distance control is out of permissible range.

Description

The order can be defined for the low-pass filter for distance control (see FCT-M3).

For axis-specific distance control using DescriptionDescription and for 3D distance control using Description.

The parameter in each case is outside the permissible range

Response

Class

1

Warning is output and correct the parameter.

Solution

Class

1

Check and correct the parameter accordingly.

Parameter

%1:

Logical axis number [-] or Logical channel number [-]

Logical axis number Axis parameters of the axis affected for axis-specific distance control,
logical channel number Logical number of a NC channel (P-CHAN-00400) for 3D distance control.

%2:

Error value [-]

Parameterised order of the low-pass filter

%3:

Lower limit value [-]

Minimum order of the low-pass filter

%4:

Upper limit value [-]

Maximum order

%5:

Corrected value [-]

Corrected order of the low-pass filter

Error type

-