ID 51086
Invalid parameters for axis coupling in escape geometry. | ||||
Description | In the Defining escape geometry (#ESCAPE PATH DEF BEGIN - #ESCAPE PATH DEF END) function, it is only possible to activate the PCS transformation with axis coupling (#TRAFO PCS [212]) if the transformation data are correctly parameterised. The logical axis number of the master axis must match the second axis index. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Possible solutions:
| |
Parameter | %1: | Current value [-] | ||
Axis index of the master axis | ||||
%2: | Expected value [-] | |||
Expected axis index for the master axis | ||||
%3: | Current value [-] | |||
Axis index of he slave axis | ||||
%4: | Expected value [-] | |||
Expected axis index for the slave axis | ||||
Error type | 1, Error message from NC program. | |||
|