Selection of the homing method (P-AXIS-00294)
P-AXIS-00294 | Selection of the homing method 'Evaluation of encoder overflow' | |
Description | This homing method is selected with the parameter P-AXIS-00294. To use this option, the parameter P-AXIS-00084 must be assigned the value 0. The number of bits used to detect encoder overflow has to be set in parameter P-AXIS-00355 . | |
Parameter | kenngr.homing_overflow_evaluation | |
Data type | BOOLEAN | |
Data range | 0: No evaluation of encoder overflow (default). 1: Evaluation of encoder overflow. | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
drive types. | Lightbus | |
Remarks | This homing method only leads to a repeatable homing position of the axis when encoder overflow occurs every time at the same mechanical position of the axis. This is true for example for resolver encoders. |