SERCOS-status/control bit for measurement (P-AXIS-00060)

P-AXIS-00060

SERCOS status/define control bit for measurement

Description

This entry defines the real time state/control bits used for probing.

Parameter

kenngr.echtzeit_bit_nr

Data type

UNS08

Data range

0 ≤ echtzeit_bit_nr ≤ 2

The real-time status and control bits are assigned according to the table below:

P-AXIS-00060

Control bits

Status bits

Measurement
Enable

measurement
done

Measuring probe
activated

0,

no entry

1

P-AXIS-00106

2

1

1

1

2

2

2

2

1

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

SERCOS

Remarks

It is recommended to set P-AXIS-00060 to either 1 or 2. The value 0 is only for backward compatibility with older version and requires additional settings (P-AXIS-00106).

If P-AXIS-00060 is assigned 1 or 2, the entry in P-AXIS-00106 is not used.