Bit number process data 'probe 2 actuated' (P-AXIS-00686)

P-AXIS-00686

Bit number process data 'probe 2 actuated'

Description

This parameter defines which bit of the process data set up in P-AXIS-00685 is used to transfer the information that probe 2 is actuated.

The last significant bit has number 0, the maximum value depends on the size of the process data used.

When the SERCOS status word is used for transmission of the 'probe 2 actuated' bit, only bit numbers 6 and 7 can be used (real-time status bits 1 and 2).

Parameter

antr.sercos.probe_2_realtime_bits.probe_actuated.bit_nr

Data type

SGN16

Data range

-1 … MAX(SGN16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

-1

Drive types

SERCOS

Remarks

If the bit number configured here is invalid, the error message P-ERR-110611 and the axis parameters P-AXIS-00118 (measuring axis) and P-AXIS-00098 (kasto_axis) are reset to prevent the execution of a measurement travel or edge banding with incompletely configured probes.