ID 110611

An invalid bit number was entered for the 'probe_actuated' signal.

Description

When configuring the SERCOS real-time status bits for the signal 'measuring probe ½', an invalid bit number was entered either in P-AXIS-00680 (probe 1) or P-AXIS-00686 (probe 2).

Response

Class

3

An error message is output containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset in order to prevent the execution of measurement run or edge banding with incompletely configured probes.

Solution

Class

1

Correct P-AXIS-00680/or P-AXIS-00686.

Parameter

%1:

 

Log. axis number

%2:

 

Incorrect value of P-AXIS-00680/or P-AXIS-00686

%3:

 

Permissible minimum value.

%4:

 

Permissible maximum value.

Error type

2, Error message on data transfer of parameter lists to controller.