ID 110611

An invalid bit number has been configured for the 'probe-actuated' signal.

Description

When configuring the SERCOS realtime status bits for the signal 'measuring probe ½', an invalid bit number was entered either in P-AXIS-00680 (probe 1) or P-AXIS-00686 (probe 2).

Response

Class

3

Output of an error message containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset, in order to prevent the execution of measurement run or edge bending with incompletely configured probes.

Solution

Class

1

P-AXIS-00680/ or P-AXIS-00686 must be corrected.

Parameter

%1:

 

Log. Axis number

%2:

 

Incorrect value of P-AXIS-00680/or P-AXIS-00686

%3:

 

Permissible minimum value.

%4:

 

Permissible maximum value.

Error type

2, Error message by data transfer from parameter list into control device.