Measurement signal via axis-specific control bit mask (P-AXIS-00115)

P-AXIS-00115

Measurement signal via axis specific control bit mask

Description

To allow external measurement signals to be taken into account as well, one bit in the axis-specific control bit mask is treated as the measurement signal. This possibility is defined by this parameter.

Parameter

kenngr.mess_signal_achs_steuer

Data type

BOOLEAN

Data range

0/1

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

----

Remarks

 

Measurement method

P-AXIS-00117
(mess_signal_taster)

P-AXIS-00116
(mess_signal_sercos)

P-AXIS-00115
(mess_signal_achs_steuer)

Drive
simulation

X

-

X

Conventional
drive interface

X

-

X

SERCOS
drive interface

X

X

X