Maximum feed of compensation movement after deselection (P-AXIS-00208)

P-AXIS-00208

Tracking mode: Maximum feed of compensation movement after deselection

Description

During active tracking, the axis can be moved out of its command position manually. This leads to a difference between the original command position and the current position. If tracking is activated while a program is executed or when manual mode is active, when tracking is deactivated, the axis is moved back to the position where tracking was selected.

This can be performed step-shaped (vb_corr_tracking = 0) or with interpolation (vb_corr_tracking != 0). The parameter P-AXIS-00258 can suppress this movement.

Parameter

kenngr.vb_corr_tracking

Data type

UNS32

Data range

0 ≤ vb_corr_tracking ≤ P-AXIS-00212

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

0

Drive types

----

Remarks