Maximum difference after deactivation (P-AXIS-00056)

P-AXIS-00056

Tracking mode: Maximum difference after deactivation

Description

After deactivating the tracking operation, the command position of the axis usually deviates from the command position when tracking mode is activated. Before interpolation is continued for an active NC program, this difference in position is reduced in order to be able to process the N program within any offsets. The parameter defines an upper limit for this deviation. If the deviation exceeds this limit, an error message is generated, while deviations lower than this parameter lead to a move back to the stored command position (see P-AXIS-00208).

Parameter

kenngr.diff_pos_tracking

Data type

UNS32

Data range

0 ≤ diff_pos_tracking ≤ MAX(UNS32)

Axis types

T, R, S

Dimension

T: 0.1 µm

R,S: 0.0001°

Default value

10000

Drive types

----

Remarks

Setting the value to 4294967295 (in version V2.11.20xx) or to a value >= 4000000000 (from CNC version V2.11.2800 onwards) deactivates monitoring of the position difference and moving back to the saved command position.