Reduced maximum speed with active G00 (P-AXIS-00155)

P-AXIS-00155

Reduced maximum speed with active G00

Description

When G00 is active, the PLC can command the CNC by a control signal to switch over to a reduced axis feed.

The control signal is sent by the “Reduced speed“ control unit.

The reaction is in real time. After a deceleration which may be required, none of the moved axes moves faster than the parameter input.

Parameter

getriebe[i].rapid_speed_red

Data type

UNS32

Data range

0 ≤ P-AXIS-00155 ≤ P-AXIS-00212

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

0

Drive types

----

Remarks

 

Reduced maximum speed with active G00
Reduced maximum speed with active G00