Maximum permissible axis velocity in security zone 2 (P-AXIS-00503)

P-AXIS-00503

Maximum permissible axis velocity in security zone 2

Description

The parameter defines the maximum permissible axis velocity inside the security zones 1 and 2 if the control signal is active.

 

Activation for security zone 2 is executed by the “Reduced velocity in zone 2“ control unit. This security zone is limited by the position limits given by P-AXIS-00105 and P-AXIS-00097.

Parameter

getriebe[i].vb_max_red_zone_2

Data type

UNS32

Data range

0 ≤ P-AXIS-00503 ≤ P-AXIS-00212

Axis types

T, R

Dimension

T: µm/s

R: 0.001°/s

Default value

0

Drive types

----

Remarks

This parameter is available as of CNC Build V3.1.3052.05 or higher.

When the parameter value is not set or has the value 0, vb_max_red_zone_2 is not active, i.e. the identical value of P-AXIS-00030.

Parameters of permissible axis velocities inside the second security zone
Parameters of permissible axis velocities inside the second security zone

Remark on active acceleration during the deceleration phase:

The effective acceleration during deceleration depends on the following factors:

If the axis is outside the zone at the time of signal activation, the axis decelerates at the acceleration value of P-AXIS-00004 . If the axis is inside the zone, the axis decelerates at the acceleration value of P-AXIS-00024 .