Option: Low pass filter (P-AXIS-00506)

P-AXIS-00506

Option: Low-pass filters

Description

The tendency for oscillation can be better suppressed by using a low-pass filter. For more information see [FCT-A7].

Parameter

kenngr.distc.low_pass_filter_enable

Data type

BOOLEAN

Data range

0: Without low pass filter

1: Low pass filter active

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

drive types.

SERCOS, Profidrive, CANopen

Remarks

In addition the following filter parameters for order and limit frequency must be configured:

P-AXIS-00507 and P-AXIS-00508