Absolute negative ACS movement limit (P-AXIS-00492)

P-AXIS-00492

Absolute negative ACS movement limit in manual mode

Description

The parameter defines the absolute negative ACS movement limit.

Parameter

handbetrieb.acs_limit_neg

Data type

SGN32

Data range

P-AXIS-00177 ≤ acs_limit_neg ≤ P-AXIS-00178

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001 °

Default value

0

drive types.

----

Remarks

If both parameters acs_limit_neg and acs_limit_pos are set to 0, the offset monitoring is inactive!