Ramp time at feedhold (P-AXIS-00360)

P-AXIS-00360

Ramp time at feedhold for manual operation without parallel interpolation

Description

The parameter defines the ramp time during active feedhold for manual operation mode.

Parameter

handbetrieb.hb.tr_feedh

Data type

UNS32

Data range

P-AXIS-00201 ≤ tr_feedh ≤ MAX(UNS32)

Axis types

T, R

Dimension

T: µs

R: µs

Default value

0

Drive types

----

Remarks

P-AXIS-00259 is output and P-AXIS-00360 is only used if parameter P-CHAN-00097 in the channel parameter list is assigned the value 1.