MCV_AxHFct

This FB signals the output of an H technology function. It is acknowledged by the PLC provided it is a technology function that was parameterised in the channel parameter list as an axis-specific output function.

Block diagram

FB parameters

VAR_IN_OUT

Variable name

Data type

Description

Axis

AXIS_REF

Axis reference

VAR_INPUT

Variable name

Data type

Description

Nr

UINT

The number of the H technology function handled by the function block is defined via the input.

Ack

BOOL

The H technology function is acknowledged on the rising edge.

VAR_OUTPUT

Variable name

Data type

Description

Active

BOOL

The output indicates the value TRUE when the technology function was output to the PLC. The output remains TRUE until a rising edge is applied to the “Ack” input.

SyncMode

DWORD

Synchronisation type of an H technology function.

This is the value used to define the synchronisation type of the H technology functions in the channel parameter list in the P-CHAN-00027 parameter.

AddNr

DINT

A number assigned to an H technology function by programming in the NC program and output when the H technology function is output to the axis-specific interface in addition to the technology function number.

See [PROG//M/H functions with additional information].

Error

BOOL

Is TRUE if an error occurs in the FB.

ErrorID

WORD

Error code