Error response of the master axis when the coupling is active (P-AXIS-00564)
P-AXIS-00564 | Error response of the master axis on camming or gearing | |
Description | This parameter defines whether the master axis stops with the same error response on occurrence of an error on the slave axis when a coupling is active. | |
Parameter | cam_gear.error_stop_master | |
Data type | BOOLEAN | |
Data range | 0: The master axis is not stopped on occurrence of an error on the slave axis 1: The master axis stops with the same error response on occurrence of an error on the slave axis | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | ---- | |
Remarks | If this parameter is set to the value 1, the master and slave axes must use the same emergency stop deceleration (see P-AXIS-00254, P-AXIS-00002, P-AXIS-00197, P-AXIS-00198) |