Error response of the master axis when the coupling is active (P-AXIS-00564)

P-AXIS-00564

Error response of the master axis on camming or gearing

Description

This parameter defines whether the master axis stops with the same error response on occurrence of an error on the slave axis when a coupling is active.

Parameter

cam_gear.error_stop_master

Data type

BOOLEAN

Data range

0: The master axis is not stopped on occurrence of an error on the slave axis

1: The master axis stops with the same error response on occurrence of an error on the slave axis

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

----

Remarks

If this parameter is set to the value 1, the master and slave axes must use the same emergency stop deceleration (see P-AXIS-00254, P-AXIS-00002, P-AXIS-00197, P-AXIS-00198)