Overview
The following parameters are available to adjust filters in the axis parameter record:
ID | Parameter | Description |
---|---|---|
P-AXIS-00319 | enable | Activates standard filter |
P-AXIS-00067 | fg_f0 | Characteristic frequency of a filter |
P-AXIS-00080 P-AXIS-00740* | guete | Quality of the filter |
P-AXIS-00140 | order | Order of the filter |
P-AXIS-00153 | prototype | Filter characteristic |
P-AXIS-00164 P-AXIS-00741* | share_percent | Signal component that is routed through the filter |
P-AXIS-00204 | type | Type of the filter |
P-AXIS-00357 | time_constant | - Use with standard filters: - Use with HSC filters: |
P-AXIS-00735 | enable | Enables standard filter of the additional interface |
P-AXIS-00739 | fg_f0 | Characteristic frequency of an additional interface filter |
P-AXIS-00740 | guete | Quality of the additional interface filter |
P-AXIS-00736 | order | Order of the additional interface filter |
P-AXIS-00737 | prototype | Filter characteristic of the additional interface |
P-AXIS-00741 | share_percent | Signal component that is routed through the filter |
P-AXIS-00738 | type | Type of the additional interface filter |
P-AXIS-00742 | time_constant | - Use with standard filters of the additional interface - Use with HSC filters: |
Parameter | Standard filters | HSC filters |
enable | X | - (**) |
fg_f0 | X (*) | X (*) |
guete | X (*) | - |
order | X | X |
prototype | X | X |
share_percent | X | X |
type | X | X |
time_constant | X (*) | X |
(*) Depending on the filter type
(**) Activated via NC command
The relevant filter parameters for each filter type are:
Filter type | Order | Character Frequency | Prototype | Time constant | Quality | Signal component |
Low-pass | X | X | X |
|
| X |
High-pass | X | X | X |
|
| X |
Band-stop | X | X | X |
| X | X |
Band-pass | X | X | X |
| X | X |
All-pass | X | X | X |
|
| X |
PT1 | (X) |
|
| X |
| X |
PT2 | (X) |
|
| X |
| X |
Delay | (X) |
|
| X |
| X |
HSC mean* | X |
| X | X |
| X |
HSC NoVib* | (X) | X | X | (X) |
| X |
(X) only to active the filter; order is calculated internally
* Can only be used as axis filter