Overview

The following parameters are available to adjust filters in the axis parameter record:

ID

Parameter

Description

P-AXIS-00319

enable

Activates standard filter

P-AXIS-00067

fg_f0

Characteristic frequency of a filter

P-AXIS-00080

P-AXIS-00740*

guete

Quality of the filter

P-AXIS-00140

order

Order of the filter

P-AXIS-00153

prototype

Filter characteristic

P-AXIS-00164

P-AXIS-00741*

share_percent

Signal component that is routed through the filter

P-AXIS-00204

type

Type of the filter

P-AXIS-00357

time_constant

- Use with standard filters:
  Time constant of the PT1, PT2 and time delay filters.

- Use with HSC filters:
  Filter order in µs [alternative to P-AXIS-00140)

P-AXIS-00735

enable

Enables standard filter of the additional interface

P-AXIS-00739

fg_f0

Characteristic frequency of an additional interface filter

P-AXIS-00740

guete

Quality of the additional interface filter

P-AXIS-00736

order

Order of the additional interface filter

P-AXIS-00737

prototype

Filter characteristic of the additional interface

P-AXIS-00741

share_percent

Signal component that is routed through the filter

P-AXIS-00738

type

Type of the additional interface filter

P-AXIS-00742

time_constant

- Use with standard filters of the additional interface
  Time constant of the PT1, PT2 and time delay filters.

- Use with HSC filters:
  Filter order in µs [alternative to P-AXIS-00140)

Parameter

Standard filters

HSC filters

enable

X

- (**)

fg_f0

X (*)

X (*)

guete

X (*)

-

order

X

X

prototype

X

X

share_percent

X

X

type

X

X

time_constant

X (*)

X

(*) Depending on the filter type

(**) Activated via NC command

The relevant filter parameters for each filter type are:

Filter type

Order

Character Frequency

Prototype

Time constant

Quality

Signal component

Low-pass

X

X

X

 

 

X

High-pass

X

X

X

 

 

X

Band-stop

X

X

X

 

X

X

Band-pass

X

X

X

 

X

X

All-pass

X

X

X

 

 

X

PT1

(X)

 

 

X

 

X

PT2

(X)

 

 

X

 

X

Delay

(X)

 

 

X

 

X

HSC mean*

X

 

X

X

 

X

HSC NoVib*

(X)

X

X

(X)

 

X

(X) only to active the filter; order is calculated internally