ID 20427

Channel parameters: Number of axes of a group is out of range of permissible values.

Description

At start-up, a check of the channel parameters detected that the real number of configured path axes P-CHAN-00007 in the axes group exceeds the permissible value range.

Response

Class

1

Controller start-up is continued.

Solution

Class

1

In case of conflict, the total number of path axes at start-up is set to the maximum permissible limit value and the start-up is continued.

Note:

The complete number of path axes configured in the channel parameter list may then not be available in the channel after start-up!

Parameter

%1:

Error value [-]

 

%2:

Limit value[-]

 

%3:

Corrected value[-]

Total number of path axes automatically corrected

Error type

2, Error message by data transfer from parameter list into control device.