ID 50262
Virtual and other axes are take part mixed at measurement. | ||||
Description | When using measurement function G100, virtual axes and axes of another drive type (P-AXIS-00020) are mixed in measurement axes group. This is not permitted. For more information on the G100 measuring function see [PROG// Section: Measuring functions] [FCT-C4]. | |||
Response | Class | 4 | Movement stop. | |
Solution | Class | 6 | Use either all axes of measurement group with drive type virtual or all measurement run with other drive type (P-AXIS-00020). | |
Parameter | %1: | Current value [-] | ||
Number of measurement axes in measurement group. | ||||
%2: | Current value [-] | |||
Programmed axes of measurement axis group. | ||||
Error type | 1, Error message from NC program. | |||
|