ID 50262

During measuring virtual and other axes must not be mixed.

Description

When using measuring function G100, virtual axes and axes of another drive type (P-AXIS-00020) are mixed in measurement axes. This is not permitted.

For more information on the G100 measuring function, see

[PROG// Section: Measuring functions]

[FCT-C4].

Response

Class

4

Movement stop.

Solution

Class

6

For the drive type (P-AXIS-00020), use either only virtual axes or no virtual axes for the axes involved in the measurement run

Parameter

%1:

Current value [-]

Number of virtual measurement axes in measurement axis group.

%2:

Current value [-]

Programmed axes of measurement axis group.

Error type

1, Error message from NC program.