ID 50558

Filter design with given parameters not possible.

Description

It is not possible to find valid filter parameters for all filter parameters, for example, due to the limited calculation accuracy. Possible solutions are:

 

Reduce order P-AXIS-00140 of the filter

Reduce the reciprocal bandwidth P-AXIS-00080 of band-pass or band-stop filters

Choose a different filter prototype P-AXIS-00153

Increase the ratio of cut-off frequency to sampling rate

Response

Class

3

Filter is deactivated

Solution

Class

7

Change filter parameters

Parameter

%1:

 

Logical axis number P-AXIS-00016 of axis affected

%2:

 

Number of filter affected

%3:

 

Filter type P-AXIS-00204

%4:

 

Filter order P-AXIS-00140

%5:

 

Filter cut-off frequency P-AXIS-00067 or time constant P-AXIS-00357 of PT1 filter/PT2 filter

Error type

-