ID 60102

Warning level of axis velocity exceeded.

Description

The maximum axis velocity set in the axis parameter list (P-AXIS-00212) was exceeded by at least 5 percent.

This error message is used for diagnosis of the dynamic look-ahead and is only output if the NC kernel is parameterised accordingly.

Response

Class

1

None

Solution

Class

1

 

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [1µm/s or 0.001°/s]

Current command velocity of the axis.

%3:

Limit value [1µm/s or 0.001°/s]

Maximum permissible velocity of the axis (P-AXIS-00212).

%4:

Current value [-]

Ratio of current velocity to maximum permissible axis velocity (absolute value).

%5:

Limit value[-]

Maximum tolerable ratio of actual velocity to maximum permissible velocity.

Error type

1, Error message from NC program.