ID 60196

Changeover velocity greater than maximum feed rate.

Description

The changeover velocity between acceleration steps 1 and 2 (P-AXIS-00221 or P-AXIS-00211) parameterised in the axis parameter list is greater than the permissible maximum velocity of the axis P-AXIS-00212.

Response

Class

1

Warning output and value is corrected on P-AXIS-00212.

Solution

Class

1

Change axis parameter list, set P-AXIS-00221 or. P-AXIS-00211 smaller than P-AXIS-00212.

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [1µm/s or 0.001°/s]

Current parametrised value either P-AXIS-00211 or P-AXIS-00221.

%3:

Limit value [1µm/s or 0.001°/s]

Limit value (P-AXIS-00212)

%4:

Corrected value [1µm/s or 0.001°/s]

Corrected value

%5:

Current value [-]

This value specifies which parameter triggered the warning:

0: P-AXIS-00221 is faulty.

1: P-AXIS-00211 is faulty.

Error type

1, Error message from NC program.