ID 60314

Axis not at standstill! Updating filter parameters not possible. Changes are discarded!

Description

A list update or the #MACHINE DATA command changed parameters of the axis filter (see [FCT-A7// Section: Parameter]). However, this is only permitted when the axis is stationary.

Response

Class

3

New parameters are not adopted

Solution

Class

7

Repeat the parameter update when the axis is at standstill

Parameter

%1:

 

Logical axis number P-AXIS-00016 of axis affected

%2:

Current value [-]

Index of the filter affected

%3:

Current value [-]

TRUE : Axis filter has reached the target position

%4:

Current value [-]

TRUE : Command values are output to the axis, i.e. the axis moves

Error type

-

 

Attention

attention

The changed filter parameters have no effect in the controller. The changes are discarded.