ID 70030
Error within machine reference search for SERCOS drive. | ||||
Description | During homing (see [FCT-M1]), an error occurred with a SERCOS drive.
Possible cause: Some SERCOS drives require a minimum distance between the reference switch and the reference mark in order to finish a drive controlled reference point traverse successfully. Otherwise the reference mark cannot be detected precisely.
Solution:
| |||
Response | Class | 5 | Abrupt axis stop | |
Solution | Class | 6 | Consult drive manufacturer's documentation | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of affected axis see P-AXIS-00016 | ||||
%2: | Drive type [-] | |||
Drive type of concerned axis, see P-AXIS-00020 | ||||
%3: | Current value [-] | |||
SERCOS drive status | ||||
%4: | Block number [-] | |||
Block number of the NC program, in which the error occurred. | ||||
Error type | 11, Error message from position controller. | |||
|