ID 70030

Error during homing of SERCOS drive.

Description

During homing (see [FCT-M1]), an error occurred with a SERCOS drive.

 

Possible cause:

Some SERCOS drives require a minimum distance between the reference switch and the position marker in order to complete drive-controlled homing successfully. Otherwise the position marker cannot be detected precisely.

 

Solution:

  • Consult the documentation of the drive manufacturer for further error diagnosis.
  • Check the ID number S-0-0298 whether the reference switch must be moved and by what distance.

Response

Class

5

Abrupt axis stop

Solution

Class

6

Consult drive manufacturer documentation

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis, see P-AXIS-00016

%2:

Drive type [-]

Drive type of axis affected, see P-AXIS-00020

%3:

Current value [-]

SERCOS drive status

%4:

Block number [-]

Block number of the NC program where the error occurred.

Error type

11, Error message from position controller.