ID 70034

No continued motion possible without homing.

Description

Unable to continue motion without homing.

 

Cause:

The limit (see P-AXIS-00220 at which the measurement system delivers faulty signals can be exceeded at higher speeds, especially with spindles. The position controller must therefore be switched to controlled operation. Therefore, start a new homing process to obtain valid actual positions again after a velocity reduction in the position controller.

 

Solution:

Start a new homing process for the axis

Response

Class

7

Closed-loop controlled axis stop

Solution

Class

6

Start a homing process

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis, see P-AXIS-00016

%2:

Drive type [-]

Drive type of axis affected, see P-AXIS-00020

%3:

Current value [-]

 

%4:

Block number [-]

Block number of the NC program where the error occurred.

Error type

11, Error message from position controller.