ID 70084

Plausib. error in leadscrew error compensation at inversion of direction.

Description

Plausibility error on direction reversal in leadscrew error compensation.

See also [FCT-C5// Section: Leadscrew error compensation]

Response

Class

7

Closed-loop controlled axis stop

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis see P-AXIS-00016

%2:

Drive type [-]

Drive type of concerned axis, see P-AXIS-00020

%3:

Block number [-]

Block number of the NC program, in which the error occurred

%4:

Current value [-]

Command value

%5:

Current value [-]

 

Error type

11, Error message from position controller.