ID 70224

Positive hardware limit switch of drive has been actuated.

Description

The drive reports that the positive hardware limit switch is actuated.

 

Possible causes:

  • Incorrect NC program.
  • Overshoot of axis is too great.

Response

Class

5

Immediate stop of the affected axis. The drive executes its own error reaction depending on its drive setting.

Solution

Class

6

Correct the NC program and check controller settings

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Drive type [-]

Drive type P-AXIS-00020 of the axis affected

%3:

Block number [-]

Block number of the NC program where the error occurred

%4:

Current value [0.1 µm or 0.0001°]

Current command position

Error type