ID 70243

Invalid resolution of slave axis for plane compensation.

Description

The compensation values for plane compensation were specified in increments in the corresponding compensation value list. This is only permitted for a measuring system path resolution of one (see P-AXIS-00234, P-AXIS-00233). However, the slave axis (the axis, which has to be compensated) uses a different path resolution than one.

 

See [COMP// Section: Plane compensation]

and [FCT-C5//Plane compensation]

Response

Class

7

Closed-loop controlled axis stop and turn off the plane compensation for the affected axis

Solution

Class

7

Change the value of parameter P-COMP-00008 in the compensation value list to one and enter the compensation values metrically (in 0.1 µm).

Parameter

%1:

Logical axis number [-]

Logical axis number of the affected slave axis see P-AXIS-00016

%2:

Error value [-]

Path resolution of measuring system of slave axis, see P-AXIS-00233, P-AXIS-00234

%3:

Expected value [-]

Expected path resolution of the measuring system, see P-AXIS-00233, P-AXIS-00234

Error type

11, Error message from position controller.