ID 70249

Invalid resolution of slave axis for cross compensation.

Description

Compensation values for cross compensation were specified in increments in the associated compensation value list. This is only permitted for a measuring system path resolution of one (see P-AXIS-00234, P-AXIS-00233). However, the slave axis to be compensated uses a path resolution unequal to one.

 

See:

[COMP// Section: Cross compensation]]

[FCT-C5// Section: Cross compensation]

Response

Class

7

Closed-loop controlled axis stop. The cross compensation is turned off for affected axis

Solution

Class

7

Change the value of parameter P-COMP-00003 in the compensation value list to one and enter the compensation values metrically (in 0.1 µm).

Parameter

%1:

Logical axis number [-]

Logical axis number of the affected slave axis see P-AXIS-00016

%2:

Error value [-]

Path resolution of measuring system of slave axis, see P-AXIS-00233, P-AXIS-00234

%3:

Expected value [-]

Expected path resolution of the measuring system, see P-AXIS-00233, P-AXIS-00234

Error type

11, Error message from position controller.