ID 70250

Invalid resolution of master axis for cross compensation.

Description

The compensation values for cross compensation were specified in increments in the corresponding compensation value list. This is only permitted for a measuring system path resolution of one (see P-AXIS-00234, P-AXIS-00233). However, the master axis whose position affects the slave axis uses a path resolution unequal to one.

 

See:

[COMP// Section: Cross compensation]]

[FCT-C5// Section: Cross compensation]

Response

Class

7

Controlled slave axis stop. And disable compensation for the slave axis

Solution

Class

7

Change the value of parameter P-COMP-00003 in the compensation value list to one and enter the compensation values metrically (in 0.1 µm).

Parameter

%1:

Logical axis number [-]

Logical axis number of the slave axis P-AXIS-00016

%2:

Logical axis number [-]

Logical axis number of affected master axis, see P-AXIS-00016, P-COMP-00005

%3:

Error value [-]

Path resolution of measuring system of slave axis, see P-AXIS-00233, P-AXIS-00234

%4:

Expected value[-] ]

Expected path resolution of the measuring system see P-AXIS-00233, P-AXIS-00234

Error type

11, Error message from position controller.