ID 70280

Value for user telegram element exceeds valid value range.

Description

With a #DRIVE WR [... TELEGR_ELEM=XXX   VAL= ...] command (see [PROG]), an attempt was made to assign a value to a telegram element XXX via VAL, which lies outside of the permissible value range for this telegram element.

See [PROG// Section: Drive-independent switching of drive functions]

Response

Class

7

Program execution stop.

Solution

Class

6

Adjust value of VAL in the NC-program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis see P-AXIS-00016

%2:

Error value [-]

In VAL-element programmed, incorrect value

%3:

Lower limit value [-]

Minimum admissible value.

%4:

Upper limit value [-]

Maximum permissible value

Error type

11, Error message from position controller.