ID 70390
Changing measuring input for drive probing not possible for this drive type. | ||||
Description | In the NC program, the #MEAS command can be used to change the measurement input during position detection in the drive. However, this is not possible for some drive types e.g. like SERCOS since for these drives there must be several parameters changed in the drive itself. For further information see: | |||
Response | Class | 7 | Controlled stop of concerned axis | |
Solution | Class | 6 | Correct NC program | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Drive type [-] | |||
Concerned drive type P-AXIS-00020 | ||||
%3: | Current value [-] | |||
Actual probing method | ||||
%4: | Error value [-] | |||
Programmed probing input | ||||
%5: | Corrected value [-] | |||
Corrected probing input | ||||
Error type | 11, Error message from position controller. | |||
|