ID 70391

Changing measuring edge for drive probing not possible for this drive type.

Description

The #MEAS command can be used to change the measuring edge (rising or falling) in the NC program. However, this is not possible with some drives (e.g. like SERCOS) when the probing value is latched in the drive, since in this case there must be several parameters changed in the drive itself.

For further information see:

[PROG// Section: Settings for measurement]

Response

Class

7

Controlled stop of concerned axis

Solution

Class

6

Correct NC program

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Drive type [-]

Concerned drive type P-AXIS-00020

%3:

Current value [-]

Actual probing method

%4:

Error value [-]

Programmed probing input

%5:

Corrected value [-]

Corrected probing input

Error type

11, Error message from position controller.