ID 70411

Filter of additional command values interface could not be generated.

Description

To smooth command values, a PT2 filter can be activated in the position controller for the additive command value interface. However, it is not possible to generate the filter with the current filter time constant P-AXIS-00438. The exact cause of the error can be found in the previous error message.

See also:

[HLI// Section: External axis commanding] for CNC build < 2800

[HLI// Section: External axis commanding] for CNC build > 2800

Response

Class

7

Filter is deactivated

Solution

Class

6

Change time constant P-AXIS-00438 of PT2 filter

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Drive type [-]

Drive type of concerned axis, see P-AXIS-00020

%3:

Current value [µs]

Time constant P-AXIS-00438 of the used PT2 filter

%4:

Error value [-]

 

Error type

-