ID 70523

Permissible distance for movement from reference cam exceeded.

Description

During homing, the maximum covered distance set in P-AXIS-00531 was exceeded when moving away from the reference cam.

Possible causes for this error message are:

  • the reference switch is ‘frozen’.
  • P-AXIS-00531 setting is too small.

Response

Class

7

Error message output, abort NC program.

Solution

Class

6

Possible remedies:

  • Check reference switch function
  • Set larger parameter in P-AXIS-00531

Parameter

%1:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of affected axis

%2:

Error value [-]

Distance covered on moving away from cam

%3:

Limit value [-]

Maximum permissible distance

%4:

Current value [-]

Current command position

Error type

11, Error message from position controller.