ID 110126

Maximum velocity for manual mode exceeds limit.

Description

The maximum velocity P-AXIS-00213 in active manual operation mode is greater than the maximum value. The maximum velocity is set to default value.

Response

Class

1

None.

Solution

Class

1

Set maximum velocity for manual operation mode P-AXIS-00213 smaller than maximum value P-AXIS-00212.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0,001°/s]

Current maximum velocity P-AXIS-00213.

%3:

Limit value [1µm/s or 0.001°/s]

Upper limit value of velocity.

%4:

Corrected value [1µm/s or 0,001°/s]

Corrected maximum velocity P-AXIS-00213.

Error type

2, Error message by data transfer from parameter list into control device.