Maximum velocity for manual mode exceeds limit. | ||||
Description | The maximum velocity P-AXIS-00213 in active manual operation mode is greater than the maximum value. The maximum velocity is set to default value. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Set maximum velocity for manual operation mode P-AXIS-00213 smaller than maximum value P-AXIS-00212. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis. | ||||
%2: | Current value [1µm/s or 0,001°/s] | |||
Current maximum velocity P-AXIS-00213. | ||||
%3: | Limit value [1µm/s or 0.001°/s] | |||
Upper limit value of velocity. | ||||
%4: | Corrected value [1µm/s or 0,001°/s] | |||
Corrected maximum velocity P-AXIS-00213. | ||||