ID 110219

Maximum speed of manual mode exceeds axis limit.

Description

The set maximum manual operation velocity P-AXIS-00213 is higher than the general maximum axis velocity P-AXIS-00212.

Response

Class

1

Velocity is limited to maximum axis velocity.

Solution

Class

1

Correct parameter in axis list.

Parameter

%1:

Logical axis number [-]

P-AXIS-00016

%2:

Error value [1µm/s or 0,001°/s]

P-AXIS-00213

%3:

Corrected value [1µm/s or 0,001°/s]

 

%4:

Instance [-]

Current gear stage P-AXIS-00136

%5:

Upper limit value [1µm/s or 0,001°/s]

Maximum axis velocity P-AXIS-00212

Error type

2, Error message by data transfer from parameter list into control device.