ID 110230
Parameter out of value range. | ||||
Description | In axis with axis type spindle P-AXIS-00018, the entry for default CAX gear stage parameter P-AXIS-00052 has an invalid value. In the rotary C axis, the #CAX command is used to change to the default CAX gear stage when the CAX function is selected. The CAX gear step is set to default value. For more information on CAX function see [PROG// Section: C axis machining]. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Use correct entry for default CAX gear stage P-AXIS-00052. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis. | ||||
%2: | Current value [-] | |||
Current default CAX gear step P-AXIS-00052. | ||||
%3: | Limit value [-] | |||
Maximum value of gear step. | ||||
%4: | Corrected value [-] | |||
Corrected default CAX gear stage P-AXIS-00052. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|