ID 110317

SGN32 Underflow: Negative software limit switch - tolerance less than MIN_SGN32.

Description

The negative software limit switch (SLS) P-AXIS-00177 is out of range. The software limit switch including the tolerance band P-AXIS-00179 must be greater than –2147483648 (minimum signed 4-byte numeral).

Response

Class

1

Value is set to minimum value.

Solution

Class

1

Correct value in parameter list.

Parameter

%1:

Logical axis number [-]

P-AXIS-00016

%2:

Current value [0.1 µm or 0.0001°]

SLS P-AXIS-00177

%3:

Current value [0.1 µm or 0.0001°]

Tolerance P-AXIS-00179

%4:

Corrected value [0.1 µm or 0.0001°]

P-AXIS-00177

Error type

2, Error message on data transfer of parameter lists to controller.