ID 110319

Unknown entry in configuration of input telegram.

Description

At start-up of the CNC kernel, the mapping between the values transmitted cyclically or to the drive, and the internal working of the drive and the internal working data of the CNC is made by entries in the axis parameter list. In one of these entries an unknown value was detected.

In the following example either value 99999 in entry antr.terminal.in[1].signal_nr or value XXXXXX in entry antr.terminal.in[1].nc_ref is invalid.

 

Example:

antr.terminal.in[1].signal_nr                               99999
antr.terminal.in[1].signal_len                              2
antr.terminal.in[1].nc_ref                                  XXXXXX

Response

Class

3

Error message output, erroneous entry is ignored.

Solution

Class

6

Correct invalid entry in the parameter list.

Parameter

%1:

Current value [-]

P-AXIS-00020

%2:

Logical axis number [-]

P-AXIS-00016

%3:

Current value [-]

Index of erroneous entry, in the example above value 1.

%4:

Current value [-]

Signal number of erroneous entry, in the example above 99999.

%5:

Current value [-]

Signal name of erroneous entry, in the example above XXXXXX.

Error type

-