ID 110361

The characteristic frequency of axis filter exceeds minimum limit.

Description

The characteristic frequency (see P-AXIS-00067) of the specified axis filter is too low. The interpretation of the characteristic frequency is dependent on the filter type:

  • Low-pass filter: Beginning of cut-off frequency range (ideal filter)
  • High-pass filters: Beginning of cut-off frequency range (ideal filter)
  • Band-pass and band-stop filters: middle frequency

Response

Class

1

Correct parameter P-AXIS-00067 to lowest permissible frequency

Solution

Class

1

Increase the characteristic frequency P-AXIS-00067 of the axis filter.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis, see P-AXIS-00016

%2:

Current value [-]

Number of filter affected

%3:

Current value [-]

Specified value for the characteristic filter frequency P-AXIS-00067 in Hertz.

%4:

Corrected value [-]

Corrected value for characteristic filter frequency P-AXIS-00067 in Hertz.

Error type

2, Error message on data transfer of parameter lists to controller.