ID 110393
acceleration for homing greater than maximum permissible value. | ||||
Description | The acceleration for the homing P-AXIS-00285 with jerk limited slope was specified to be greater than the maximum permissible acceleration P-AXIS-00008. | |||
Response | Class | 1 | Limitation of acceleration with maximum value | |
Solution | Class | 1 | Setting of acceleration for homing smaller than maximum value. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of concerned axis P-AXIS-00016. | ||||
%2: | Current value [1mm/s^2 or 1°/s^2] | |||
Current acceleration P-AXIS-00285. | ||||
%3: | Upper limit value [1mm/s^2 or 1°/s^2] | |||
Maximum permissible acceleration P-AXIS-00008. | ||||
%4: | Corrected value [1mm/s^2 or 1°/s^2] | |||
Corrected acceleration P-AXIS-00285. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|