ID 110393

acceleration for homing greater than maximum permissible value.

Description

The acceleration for the homing P-AXIS-00285 with jerk limited slope was specified to be greater than the maximum permissible acceleration P-AXIS-00008.

Response

Class

1

Limitation of acceleration with maximum value

Solution

Class

1

Setting of acceleration for homing smaller than maximum value.

Parameter

%1:

Logical axis number [-]

Logical axis number of concerned axis P-AXIS-00016.

%2:

Current value [1mm/s^2 or 1°/s^2]

Current acceleration P-AXIS-00285.

%3:

Upper limit value [1mm/s^2 or 1°/s^2]

Maximum permissible acceleration P-AXIS-00008.

%4:

Corrected value [1mm/s^2 or 1°/s^2]

Corrected acceleration P-AXIS-00285.

Error type

2, Error message by data transfer from parameter list into control device.