ID 110406

Minimum for weighted ramp time is smaller than minimum permissible ramp time.

Description

The minimum for ramp time P-AXIS-00293 with weighting using function G132/G133 is smaller than the minimum permissible ramp time P-AXIS-00201.

Response

Class

1

Increase ramp time P-AXIS-00293 to the minimum permissible ramp time.

Solution

Class

1

Increase ramp time P-AXIS-00293

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis see P-AXIS-00016

%2:

Current value [1 µs]

Specified minimum for weighted ramp time, see P-AXIS-00293

%3:

Limit value [1 µs]

Minimum permissible ramp time, see P-AXIS-00201

%4:

Corrected value [1 µs]

Corrected minimum for weighted ramp time, see P-AXIS-00293

Error type

2, Error message on data transfer of parameter lists to controller.