ID 110409

Phasing-velocity is inadmissible.

Description

The phasing velocity P-AXIS-00305 for the synchronization at camming must not be zero or greater than the half of the maximum permissible axis velocity P-AXIS-00212.

Response

Class

1

Warning output. The value of P-AXIS-00305 is automatically set to the half of the maximum permissible axis velocity P-AXIS-00212 .

Solution

Class

1

Set value for P-AXIS-00305 greater than zero (nil) and less than the half of the maximum permissible axis velocity P-AXIS-00212.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0,001°/s]

Current value of P-AXIS-00305.

%3:

Corrected value [1µm/s or 0,001°/s]

Corrected value of P-AXIS-00305.

Error type

2, Error message by data transfer from parameter list into control device.